* HP MODEL A2094A MONITOR *
* *
* QUALITY ASSURANCE INFORMATION *
* *
* *
**************************************************************************
* *
* February 1993 *
* *
* FOR INTERNAL USE ONLY *
* *
**************************************************************************
SAFETY
The HP Model A2094A 19" High Resolution 72HZ Color Monitor was designed
manufactured and marketed in compliance with published safety standards stated
below. Qualification testing was done with one unit representative of the
product shipped to the customer. Continued compliance is measured by periodic
regulatory audits; production units are tested for each audit. The Model A2094A
is in compliance with the following safety standards:
Underwriter's Laboratories (USA)
* UL file : E 73362
* UL compliance date: 8/92
- UL 1950 Information Technology Equipment.
As evidence of UL listing, the products are marked with the UL logo.
Canadian Standards Association (Canada)
* CSA file LR 50776
* CSA compliance date: 9/92
- CSA 22.2 No. 220-M1986 Information Processing & Business Equipment
As evidence of CSA certification the products are marked with the CSA
monogram.
TUV Rheinland (German)
* GS Approval for Color Display Monitor
TUV GS License Number S 95647
- IEC 950/EN60950 Safety of Information Technology Equipment including
Electronic Business Equipment.
===========================================================================
ELECTROMAGNETIC STANDARDS
The Model A2094A is in compliance with published standards for Electro-
magnetic Compatibility (EMC). Qualification testing was done with several
units of the Model A2094A which were representative of the product shipped
to customers. Continued compliance is measured by periodic regulatory
audits; production units are tested for each audit. The Model A2094A is in
compliance with these EMC Standards:
Federal Communications Commission (USA)
- FCC: Code of Federal Regulations, Title 47, part 15, Radio Frequency
Devices, Subpart J Computing Devices.
The Model A2094A has an FCC Class A label attached.
European Economic Community
- EMC Directive 89/336/EEC
The Model A2094A has a CE mark attached.
* Voluntary Control Council for Interface (Japan)
- CISPR: Publication 22, Limits and Methods of Measurement of Radio
Interference Characteristics of Information Technology Equipment.
(data processing equipment and electronic office machines).
The Model A2094A is registered by VCCI as a Class 1 product and carrie
a VCCI label as evidence of this registration for Japan.
-------------------------------------------------------------------------
ELECTROMAGNETIC COMPATIBILITY TESTING
RADIATED
Operating
Test Summary: CISPR 22 class A from 10 KHz to 1 GHz
Test Results: Passed
Operating
Test Summary: FCC class A from 30 MHz to 1 GHz
Test Results: Passed
Operating
Test Summary: VCCI Class 1, CISPR 22, 30 MHz to 1 GHz
Test Results: Passed
CONDUCTED
Operating
Test Summary: CISPR 22 class A from 10 KHz to 30 MHz
Test Results: Pased_
Operating
Test Summary: FCC class A from 450 KHz to 30 MHz
Test Results: Passed
Operating
Test Summary: VCCI Class 1 CISPR 22, 15 KHz to 30 MHz
Test Results: Passed
RADIATED IMMUNITY
Operating
Test Summary: EN55024-3, 3V/M
Test Results: Passed
ESD
Operating
Test Summary: EN55101-2, 3KV CD, 8KV AD
Test Results: Passed
===========================================================================
ACOUSTICS STANDARDS
The HP Model A2094A was designed without fans. A 70dB declaration is included i
the manual.
ERGONOMICS STANDARDS
The HP Model A2094A was designed to comply with ZH-1/618 Edition: 10/80,
"Safety Regulations for Display Work Places in the Office Sector", and MPR1990:8
Test Method for Visual Display Units, and MPR 1990:10 User's Handbook for
Evaluating Visual Display Units.
===========================================================================
ENVIRONMENTAL RUGGEDNESS
The Model A2094A is designed for use in an environment which involves
moderately high and low temperatures, humidity variations and occasional
vibration. Samples of the Model A2094A, representative of customer
shippable units, have been tested prior to the release of the units to
manufacturing. The products were evaluated in a variety of configurations
for each environmental test, so that worst case situations for all environ-
ments were tested. The numbers shown under "Test Results" are accurate as
of the date of this publication. Presentation of the test data does not
imply a guarantee of performance; a brief description of testing and
results for the monitor, follow in the section entitled "Test Summary
and Test Results"
In addition to these tests the Model A2094A was subjected to more severe
tests during the product development stage. These development tests were
designed to cause product failure so that the failure mechanisms are
understood and eliminated when possible.
***************************************************************************
TEST SUMMARY and TEST RESULTS
TEMPERATURE (LT = low temperature, HT = high temperature)
LT Operating
Test Summary: Stabilize to 10 degrees Celsius, test performance
Test Status: Completed
LT Survival
Test Summary: Stability to -40 degrees C, return to -5 degrees
test performance
Test Status: Completed
HT Operating
Test Summary: Stabilize to +40 degrees C, test performance
Test Status: Completed
HT Survival
Test Summary: Stabilize to +60 degrees C, return to +40 degrees
test performance
Test Status: Completed
---------------------------------------------------------------------------
HUMIDITY (RH - relative humidity)
Operating
Test Summary: Stabilize 40 degrees C and 95% RH, performance
periodically tested. (RH non-condensing)
Test Status: Completed
Condensation - Abnormal
Test Summary: Stabilize 25 degrees C and 50% RH; transfer 40 de
C, 95% RH, apply power, wait 5 minutes, test. Full
recovery in 15 minutes.
Test Status: Completed
VIBRATION (Tests are repeated on each of 3 orthogonal axes.)
Random Vibration - Operating
Test Summary: Levels (5 - 350 Hz) at 0.0001 G^2/Hz
(350 - 500 Hz at - 6dB/Octave (to 0.0005 G^2/Hz
0.21 Grms Unit performs to specifications during test.
Test Status: Completed
Swept Sine - Survival
Test Summary: 5-500-5 Hz, 1 Octave/min., 0.5 G ( 0 to peak), Sw
sine, 5 minute dwell at each of 4 lowest resonant performance.
Test Status: Completed
Random Vibration - Survival
Test Summary: Levels (5-100 Hz) at 0.015 G^2/Hz;
(100 - 137 Hz) at -6dB/Octave;
(137 - 350 Hz) at 0.0080 G^2/Hz;
(350 - 500 Hz) at -6dB/Octave.
500Hz at 0.0039 G^2/Hz
2.09 Grms
Test Status: Completed
---------------------------------------------------------------------------
SHOCK
End Use - Abnormal
Test Summary: 32 inches per sec., less than 9.0 millisec. durat
(approx. 22 G), 1/2 sine wave Shock Pulse, powered on,
unpackaged unit secured to shock table, 1 shock on each
of 6 faces, cycle power, test performance.
Test Status: Completed
Transport - Survival
Test Summary: 20 G, 189 inches per sec.(approx. 20 millisec.
duration)
Trapezoidal Shock Pulse. Unpackaged unit secured to
shock table, 1 shock on each of 6 faces, test
performance.
Test Status: Completed
---------------------------------------------------------------------------
ALTITUDE
Operating - Normal
Test Summary: Operate at 10,000 ft. (8.29 psi), 12 degrees C fo
hr
Test Status: Completed
---------------------------------------------------------------------------
TRANSPORTATION
Package Drop - Survival
Test Summary: Packaged unit dropped from 38cm height on 6 surfa
corners, test performance.
Test Status: Completed
Package Vibration (Sine) - Survival
Test Summary: 5 to 200 to 5 Hz at 0.5 G (0 to peak) Resonant se
one octave per min. sweep rate, 5 minute dwell at
resonance, 11 minutes in each of 3 axes.
Test Status: Not Done
Package Vibration (Random) - Survival
Test Summary: PSD 0.015 G^2/Hz from 5 to 50 Hz, -6db per Octave
slope to 200 Hz at 0.0038 G^2/Hz. Packaged unit tested on 3
axes, 30 minutes/axis.
Test Status: Completed
-------------------------------------------------------------------------------
ELECTROMAGNETIC COMPATIBILITY
SUSCEPTIBILITIES
ESD - Operating
Test Summary: ESD probe discharge of 0 to +10 KV to all operato
accessible surfaces; checked for normal operation.
No soft failures.
Test Status: Completed
ESD - Abnormal
Test Summary: Greater than or equal to 10 KV to +25 KV. Test s
as above, no hard failures.
Test Status: Completed
Magnetic - Operating
Test Summary: Gauss peak to peak, 47.5 to 198 Hz
Exposure to .04 gauss peak to peak, 47.5 to 198 Hz, AC
field, 3 orthogonal axes, increment frequency at 1 Hz
increments.
Test Status: Completed
Conducted - Operating
Test Summary: AC signal sweep 50 KHz to 400 MHz, 1 Vrms, 80%
amplitude modulated at 1KHz on power cord hot line, repeated on
neutral line.
Test Status: Completed
Power Line Variations - Abnormal
Test Summary: 110V/220V + or - 9%, 47 to 66 Hz
12% below minimum rated line voltage, frequency varied
47 to 66 Hz (steady state).
12% above maximum rated line voltage, frequency varied
47 to 66 Hz (steady state).
500 ms transients: Less than 85% of minimum rated line
voltage. Greater than 120% of maximum rated
line voltage
Test Status: Completed
Blackout - Abnormal
Test Summary: 90 V to 0 V, greater than or equal to 18ms, (Typi
battery backups operate in less than or equal to 12
millisec.). Blackout with no failures.
Test Status: Completed
Spikes - Abnormal
Test Summary: + or - 1KV, 800 nanosec, 1 nanosec rise time, syn
-90, +120 phase, hot & neutral; and 100 spikes per sec.
at 1 KV, no phase sync. (Low energy)
Test Status: Completed
Spikes - Abnormal
Test Summary: 3 KV peak, 1 pulse per sec., 100 KHz damped
oscillation Ring Wave (Low energy)
Test Status: Completed
Spikes - Abnormal
Test Summary: 1K Volts peak, 1.2 microsec. rise time, 50 micros
decay to half peak, 10 spikes, 1 spike per 10 seconds.
(High energy)
Test Status: Completed
INTERFERENCES
Magnetic
Test Summary: Magnetic field measured at surface of top, bottom
each side. Less than 1 Gauss peak to peak, 0 to 250 Hz
(Degauss cycle on monitors not included)
Test Status: Completed
RELIABILITY
Annualized Failure Rate (AFR) = 6% Yr (Model A2094A with __ Mbytes RAM).
The estimated AFR is based on parts count and the failure rates of
those parts in similar products. The AFR is estimated from the sum of
the failure rates of the component assemblies.
Mean Time Between Failure (MTBF) = 16.6 years (Model A2094A with __ Mbytes RAM),
where MTBF = 1/AFR. A key assumption is that AFR is constant beyond the early
life of the product and before long-term wearout.
Projected Failure Rate is the mature AFR, estimated from the failure rates
of the components of the product. The "Estimated Long-Term Annualized
Failure Rate" is a future projection of an average realistic failure
rate beyond the typical infant failure period which occurs in the first
few months of use and before long-term wearout which occurs after many
years of use. This product assumes an 8000 hour usage year, which is
91% duty. Actual customer experience may vary slightly.
***************************************************************************
QUALITY FLOWCHART
The Model A2094A is designed to comply with all necessary regulatory
agency requirements for safety and environmental standards, and
Hewlett-Packard has ensured that additional environmental ruggedness
specification and reliability requirements are designed in. Finally, great
care is taken to consistently manufacture these features into each product
and operate an audit program which maintains these features. Here is a
flowchart of the major quality checkpoints in the manufacturing process:
MANUFACTURING PROCESS
Incoming Quality Assurance
- Inspect mechanical parts for which we have no historical data. Provid
feedback to vendors. (Electronic components with less than 100 parts
per million failure rate are not inspected).
- 100% of new parts tested.
Clean and Inspect
- Soldered PC boards with active components cleaned and inspected.
- 100% of boards sensitive to heat or water tested.
Functional Board Test
- PC board tested with active components on HP 3065. Processor board
functionally tested with throughput tester.
- 100% of boards tested.
Unit Aging and Test
- Temperature cycled: 0 degrees C to + 50 degrees C, 8 cycles, approx. 6
minutes per cycle while functionally tested. Power cycled 16 times, o
at each extreme; others random.
- 100% of units tested.
Turn on and Final Test
- Assembled product is powered up and tested with extensive software tes
- 100% of units tested.
***************************************************************************
SYSTEM HARDWARE AUDITS
Periodic hardware audits of HP Model A2094A bundled systems are scheduled to
be conducted. Audits are performed to assist Exeter Computer Manu-
facturing Operation in verifying continuing product quality. The audit
scope is defined in HP System Audit Flowchart A-5959-6347. An audit
procedure specification for the Model A2094A which defines actual audit
tests and test limits will be used. The audit test includes the following
categories. Safety, EMC, Software, Environmental and Workmanship.
Audit Reports are distributed monthly to key partners. These reports
describe the audit findings. A Corrective Action Request (C.A.R.) is also
written and distributed to appropriate persons.
***************************************************************************
THIS DOCUMENT IS INTENDED ONLY FOR GENERAL INFORMATION PURPOSES. THE TEST
RESULTS REPORTED HAVE NOT BEEN VERIFIED TO THE EXTENT NECESSARY TO EXTEND
ANY GUARANTEE OF ACCURACY, AND HEWLETT-PACKARD SPECIFICALLY DISCLAIMS ANY
AND ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH
RESPECT TO THE INFORMATION IN THIS DOCUMENT.
THE INFORMATION PRESENTED IS SUBJECT TO CHANGE WITHOUT NOTICE.
FOR SPECIFIC WARRANTIES, CONSULT THE INDIVIDUAL PRODUCT TECHNICAL
SPECIFICATION SHEET.
Copyright Hewlett-Packard Co. 1992